Huawei console port settings. … Check the settings of serial port terminal software.

Huawei console port settings You can use the console port or Mini USB port as the serial port according to your needs. Transmission rate Modifications to console user interface attributes take effect immediately. USB port. Configuring Remote Login Through STelnet. The settings of the preceding physical attributes on the device must be the same as those on the Next time you can simply double-click the saved settings under Saved Sessions to log in to the server. Console port. Port Connector Type Description Available Components; Combo ports (0 to This text is a guide detailing Basic Command Line Interface (CLI) Commands on Huawei brand switches. Parameter. <HUAWEI> display user-interface Idx Type Select the port according to your requirements. Select the connected port based on actual situations. MGMT port---Table 2-11 Ports on the USG6000E-S13. In the right pane, type the IP address of a storage system's management network port in the Host Name (or IP address) text box. Check whether the serial cable is securely If you press and hold the PNP button for more than 6s, the device restores the default settings and restarts automatically. Information displayed in the HyperTerminal window may vary according to the router type. Connect A PC may have multiple connection ports; therefore, the port connected through the console cable is selected in this example. None. First Login Through the Management Port. Choose Connection HUAWEI S Series Switch-Configure Login Through a Console Port video demonstrates how to log in to a switch through a console port. Version:V200R021C00. This operation clears the service configuration and data files, which is the same as the function of the reset factory-configuration command. Action. File Management. If the login is successful, the server host name is displayed on the left of the prompt. A PC may have multiple Select the port according to your requirements. If you can log in to the authentication interface Select the port according to your requirements. Guides you through basic configurations, Configure terminal emulation software, set the connected port and communication parameters, and log in to the Switch. you can press and hold the PNP button for more than 6 seconds to restore the switch to factory settings and restart the switch. Before logging in to the device through the console port, complete the following tasks: Prepare the console cable. Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-6 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-6 Setting the port for connection and communication parameters. bat. ) Click Session to create a connection, as shown in Figure 2-2. Check whether the COM port settings on the PC are consistent with the console port settings on the device. ) Figure 1-2 Port connection configuration page. Configuring Login Through the Mini USB Port. 5-Service port indicator. < HUAWEI > clock timezone BJ add 08:00:00 < HUAWEI > clock datetime 20:20:00 2018-08-08. Table 3-139 Ordering information. If the console user interface uses the default attribute settings and Check that the serial port settings on the PC are the same as the console port settings on the device, as shown in Figure 1. 168. <Quidway> unzip vrptest vrpcfg. For example, you can view port information in Device Manager in the Windows operating system, and select the connected port. Ensure that the communication parameters you set in the terminal emulation software are consistent with the default parameter settings of the switch's console port. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user interface on the device, which are 9600 bit/s baud rate, 8 data bits, 1 stop bit, no parity check, The settings of the terminal communication parameters must be consistent with those of the physical attribute parameters on the user interface of the console port. user-interface console 0 [Huawei-ui-console0] authentication-mode password [Huawei-ui-console0] set authentication password cipher Enter Password(<8-128>): [Huawei-ui-console0 it restores the default factory settings Connect the RJ45 connector of the console cable to the CONSOLE interface (RJ45) of the router. The default authentication mode for login through the console port is AAA authentication. <HUAWEI> Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-5 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-5 Setting the port for connection and communication parameters. Switches are preconfigured with the URL (register. Troubleshooting CLI-based Device Login Failure. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user interface on the device, which are 9600 bit/s baud rate, 8 data After logging in to the device for the first time through the console port, perform basic configuration, and set the user level to 15 and authentication mode to AAA for users 0-4 who perform remote login through Telnet. Check whether the serial cable is securely Logging In to a Device Through the Console Port. Check whether the serial cable is securely This section uses a Huawei router as an example to describe how to clear a console port password. Before setting the current date and time, \Documents and Console port login is the basis for other login methods. No parity check The following information is only for reference. By default, the users on the console user interface are at level 15. Check the settings of serial port terminal software. The port must use a console cable. If necessary, replace the current cable with a properly-functioning one. Insert the USB device into the endpoint's USB port. Ensure that flow control is disabled, a correct port is selected, and Baud rate is set to 9600 (default setting). Create a connection, select the connection port, and set communication parameters. Check whether the serial cable is securely Run user-interface console 0. Configuring STelnet Login. Table 3-139 provides the ordering information. Part Modifications to console user interface attributes take effect immediately. Data bit. Run user privilege level level. bat 5. clock timezone time-zone-name { add | minus} offset. Start the terminal simulation software, create a connection, configure the connected port, and set communication parameters as follows. Parity. huawei. Decompress the vrptest file and name the decompressed file vrpcfg. The text covers tasks such as creating a user, VLAN configuration, port settings, enabling SSH and Telnet services, configuring Spanning Tree Restart the serial port management program and check the settings of bits per second, data bits, parity, and stop bits. Description Part Number Model First supported version; USG6635F(HTM) AC Host(8*GE COMBO + 4*GE RJ45 + 10*10GE SFP+ ,2 AC POWER) 02353WAV: USG6635F-AC This section uses a Huawei router as an example to describe how to clear a console port password. After completing the console user interface configuration on a device, you can log in to the device through the console port. The port number is MEth0/0/0 and the default IP address is 192. You can Select the port according to your requirements. Configuring Remote Login Through Telnet. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user interface on the device, which are 9600 bit/s baud rate, 8 data bits, 1 stop bit, no parity check, Before configuring device login through a console port, you have completed the following tasks: Prepare a console cable. If you log in to the switch through Telnet or STelnet, your connection with the switch will be lost after the switch is restored to factory settings. online is 0, and How to Login Huawei OLT Through Local Console / Serial Port ? [boxads] When you need to maintain and manage the Huawei equipment ( include OLT / MDU / Switch / Router and so on ) locally, you can log in to the system through the local serial port. Communication parameters of the terminal emulation software must be consistent with the Huawei Partner University. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user Table 2-1 lists the default attribute settings of a console port. 6. iMaster NCE-Campus can synchronize site Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-5 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-5 Setting the port for connection and communication parameters. Table 2-1 Default attribute settings of a console port. If you cannot log in to a device remotely, you can log in to the device locally through the console port. Run the Huawei support community is a communication center for sharing experiences and knowledge, solving questions and problems for enterprise partners, customers and engineers. If you press and hold the RST button for 5 seconds and then release the RST button, the device restores its default settings and restarts. admin Sent username "admin" admin@169. Check whether the serial cable is securely A PC may have multiple connection ports; therefore, the port connected through the console cable is selected in this example. Select the port according to your requirements. By default, flow control parameters are not set on the console interface. Learn more Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-6 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-6 Setting the port for connection and communication parameters. naas. Before setting the current date and time, \Documents and Login through the console port is the most basic mode and the basis for configuring other login modes. Default Setting. Username:huawei Password: Info: The max number of VTY users is 8, Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-6 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-6 Setting the port for connection and communication parameters. Click Serial and set the port to be connected and the communication parameters, as shown in Figure 3-3. Performing Basic Configurations After the First Login such as IP spoofing. 8. The system uses the factory settings now. You can purchase hard disk from Huawei if needed. A PC may have multiple If you log in to the device through a console port, only password authentication is required. Connect the management PC to the device's management network interface for login through the web UI. Use the USB configuration tool to import the configuration file to a USB device. If the serial port communication parameters of the device are modified, modify the communication parameters on the PC accordingly (ensure that the parameter values are the same) and re-establish the connection. Figure 4-6 shows the Console Redirection screen. Install the terminal emulation software on the PC. Maintaining the Device CLI. The PuTTY window is displayed prompting you to enter your user name next to login as. If the CLI is used, for the first login, use a console cable to connect the management PC's console port to the device's management network interface. The default transmission rate is 9600 bit/s. Figure 1 Serial port login parameter settings in SecureCRT. The serial port can be used for transferring files when the management interface fails. Cookie Settings Report content . Interconnection between iMaster NCE-Campus and CampusInsight: iMaster NCE-Campus allows for unified O&M and management, and CampusInsight can be invoked as a proxy service. If the current privilege level of a user is 3 or 15, the user has the permission to set a new console port password. No parity check [Switch-aaa] local-user admin123 password irreversible-cipher Huawei@6789 //Create a local user named admin1234 and set its password to Enterprise Products, Solutions and Services for Enterprise; Consumer Smartphones, PC & Tablets, Wearables and More; Corporate About Huawei, Press & Events , and More Three methods are provided to recover the console port password. By default, you can log in to a device directly through the management port. During the first console port login to the switch, you need to When you need to maintain and manage the Huawei equipment ( include OLT / MDU / Switch / Router and so on ) locally, you can log in to the system through the local serial port. Check whether the serial cable is securely This guidance will show you the firewall configuration for typical scenarios, followed by 8 advanced firewall settings. To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user interface on the device, which are 9600 bit/s baud rate, 8 data bits, 1 stop bit, no parity check, Prepare a serial cable used to connect the serial port on the controller enclosure and a network port on the maintenance terminal, and label the cable. The console user interface view is displayed. If you forget the password for logging in through the console port or you want to change the password, use either of the following two methods to set a new password. add: adds the specified time zone offset to the Coordinated Universal Time (UTC). BootROM Your account and network information will be used to help improve your login experience. <HUAWEI> system-view < Huawei > system-view [Huawei] user-interface console 0 [Huawei-ui-console0] authentication-mode password [Huawei-ui-console0] set authentication password cipher Warning: The "password" authentication mode is not secure, Check that the serial port settings on the PC are the same as the console port settings on the device, as shown in Figure 19-16. < HUAWEI > system-view [HUAWEI] user-interface console 0 //Enter the console user interface. Hardware: Console port: RJ45: The console port is connected to a console for on-site configuration. Modifications to console user interface attributes take effect immediately. After switches are connected to the network, For details about web settings, see Client Configuration in the S300, S500, S2700, S5700, and S6700 Set the connected port and communication parameters. Procedure. How to Buy Ask the Chatbot. When you forget the password for logging in through the console port, use either of the following two methods to set a new password. (The following figure is for reference only. Table 3-8 Default settings of the console port. FAQ About CLI Login. and connect the RJ45 connector to the console port on the device, as shown in Figure 3-5. No parity check Info: Current mode: Monitor (automatically making switching decisions). Temporary Software Authorization Application. [HUAWEI] user-interface console 0 [HUAWEI-ui-console0] authentication-mode password [HUAWEI-ui-console0] set After logging in to a switch for the first time through the console port, perform basic configurations, and set the user privilege level to 15 and authentication mode to AAA for users 0-4 who log in remotely through Telnet. When the Mini USB is activated, the console port cannot be used. Table 5-1 describes the default parameter settings of the switch's console port. 1. The endpoint restarts automatically. Table 3-3 Default attribute settings of a console port. Download file to Flash through serial After connecting a serial port to a maintenance terminal through a serial cable, you can manage and maintain the storage system through the serial port. How to Log In to the Router Through the Management Port (Web) Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-5 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-5 Setting the port for connection and communication parameters. Port Connector Type Description Available Components; HDD/SSD Hard disk slot-The hard disks This button enables you to restore the default settings with one click. For details, see Example for Configuring Switch Login Through a Console Port. When restoring factory settings, you are advised to log in to the switch through the console port. Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-5 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-5 Setting the port for connection and communication parameters. <Huawei> Info: The entered password is the same as the default. Logging In to the Switch Through STelnet or Telnet to Set a New Password. . CX22EFFE (Ver124, Jun 9 Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-6 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-6 Setting the port for connection and communication parameters. After a device is powered on, the management port (GigabitEthernet 0/0/0) is automatically bound to This button can enable you to restore the default settings with one click. On the Console Redirection screen, you can configure serial port settings. For security purposes, you are advised to set a console port password. Indicators and Buttons. HUAWEI S series switch link The console port is provided on all device models. Guides you through basic configurations, including logging in to the device, restoring factory settings and passwords, installing patches, using FTP, and applying for licenses. If you cannot log in to a switch remotely, connect a PC to the console port of the switch for local login. Correct serial port management program settings are as follows: Bits per second: 115200; Data bits: 8; Parity: none; Stop bits: 1; On the maintenance terminal, retry the login through the serial port. Transmission rate. For details on how to prepare labels, see "Preparing Cables and Connectors" in the General Cable Operation Guide. If the user level configured for a user interface conflicts with that configured for a user, the user level configured for the user takes precedence. contact Huawei switch distributors or local Huawei representative office. Case in Chinese; Help us to Select the port according to your requirements. Connect the RJ-45 end of an RJ-45 to DB9 serial cable to the serial port on the controller enclosure. Default Value. Choose Connection > Data. Web System Login Configuration. (The third-party software PuTTY is used as an example here. Configure the authentication mode of the console user interface. Flow control. Enter the interface view. System Startup Configuration. Log in to the switch after the restart. Ensure that the communication parameter settings in the terminal 3. [HUAWEI] user-interface console 0 [HUAWEI-ui-console0] authentication-mode password [HUAWEI-ui-console0] set Table 3-3 lists the default attribute settings of a console port. Select the port based on actual situations. You are advised to change it to ensure security. Enter the administrator password of the touchscreen as prompted. 4. The following figure shows the A connection should be established between the ethernet port of the terminal and the console port of the router. ZTP Configuration. Reboot (Press Ctrl+E to enter diag menu) Enter your choice(1-8): 2 SERIAL SUBMENU 1. Check whether the maintenance terminal receives messages Three methods are provided to recover the console port password. Configuration Process. Asistencia Centro de documentación Security Products Recommend USG Configuración y puesta use a console cable to connect the management PC's console port to the device's management network interface. [HUAWEI Modifications to console user interface attributes take effect immediately. Connect the DB9 connector of the console cable to the serial interface (COM) of a management PC. Figure 4-30 Indicators on the Switch. The console port is a serial port on a main control board. 5-inch hot-swappable SATA hard disk (240 GB, 960 GB, 1000 GB or 1920 GB) from Huawei. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user interface on the device, which are 9600 bit/s baud rate, 8 data bits, 1 stop bit, no parity check, and no flow control. Purchase a 2. 2008-2010 HUAWEI TECH CO. Click Open. but can be upgraded to the latest software version to obtain default settings. Huawei Partner Marketing WorkSpace. The default console port settings are as follows: Baud rate: Shows how to connect a PC to a switch with a console cable, set terminal software parameters, and log in to the switch through the console port. In the Login details text box in the right pane, type the user name of the login authentication mode to be modified. Description. If the login fails, check whether the device uses factory default settings. The console port is used when a switch Use the terminal emulation software to log in to the device through the console port. Parameter Default Setting; Transmission rate: 9600 bit/s: Flow control mode: None: Parity bit: None: Stop bit: 1: Data bit: Three methods are provided to recover the console port password. < HUAWEI > clock timezone BJ add 08:00:00 < HUAWEI > clock datetime 20:10:00 2012-07-26. , LTD. Local login through the console port is of high rights. To be specific, you can press and hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device. Command. Start PuTTY on the PC (PuTTY is an example terminal emulator). Web UI-based Login Configuration. Insert the DB9 connector of the console cable delivered with the product to the 9-pin serial port on the PC, and insert the RJ45 connector to the console port of the device. Related resources. A user level is set. Use the terminal emulation software to log in to the device through the console port, and complete basic configurations for the device. Parity check. Console cable. Playlist 1. Enter your user name and password. Transmission rate Table 4-13 Default settings for the device console port. Figure 1-6 Cable connections to the This document describes how to clear the old password or set a new password when you forget the console port login password, STelnet/Telnet login password, BootROM/BootLoad password, or web login password. After logging in to a switch for the first time through the console port, perform basic configurations, and set the user privilege level to 15 and authentication mode to AAA for users 0-4 who log in remotely through Telnet. Material preparation:1. For example, on Windows, you can open Device Manager to view port information and select the port to be connected. Huawei S5700 series switches provide simple QoS configuration methods — MQC and ACL-based simplified traffic policies. No parity check [Switch-aaa] local-user admin123 password irreversible-cipher Huawei@6789 //Create a local user named admin1234 and set its If you forget the password for logging in through the console port or you want to change the password, use either of the following two methods to set a new password. 7. user-interface console 0 [Huawei-ui-console0] authentication-mode password [Huawei-ui-console0] set authentication password cipher Enter Password(<8-128>): [Huawei-ui-console0 it restores the default factory settings This button can also be used to restore the default settings with one click. For details, see Table 4-89. If the ACT indicator on the main control board is steady on, it indicates that the How to Login Huawei OLT Through Local Console / Serial Port ? [boxads] When you need to maintain and manage the Huawei equipment ( include OLT / MDU / Switch / Router and so on ) locally, you can log in to the system through the local serial port. 254. This section uses a Huawei router as an example to describe how to clear a console port password. Note: This is an automatic approval process. The default settings are as follows: 9600 bit/s baud rate, 8 data bits, 1 stop bit, no parity check, and no flow control. minus: subtracts the specified time zone The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Stop bits: 1; Parity: None; Flow control: None; Check whether the serial cable is securely connected and functions properly. <HUAWEI> save logfile //Collect user logs. Material preparation: 1. Table 4-6 describes the parameters. Connect the RJ-45 end of an RJ-45 to DB9 serial cable to a serial port on the controller Table 3-13 Default settings for the device console port. Table 3-8 Default settings for the device console port. If there is no DB9 serial port on your terminal (PC), use a DB9-to-USB cable to connect the USB port to the terminal. Generally, COM1 is used. Meanings of service port indicators vary in different modes. MGMT port---Table 3-83 Ports on the USG6610E. Clear password for console user 8. You can connect this port to the network port or any reachable port on a PC through an Ethernet cable. The console port is connected to a console for on-site configuration. Connect the DB9 connector of the prepared console cable to the PC's serial port (COM), and the RJ45 connector to the device's console port. The default settings of the console port are as follows. Configuring Local Login Through a Console Port. Perform operations as prompted. Check whether the serial cable is securely . Run the execute command to invoke the original configuration and delete the console login password. After connecting a serial port to a maintenance terminal through a ser Logging in to a device through the console port is one of the most commonly used device management methods on the live networks. By default, the device host name is HUAWEI. This document describes the configurations of Basic, including CLI Overview, EasyDeploy Configuration, Logging In to a Device for the First Time, CLI Login Configuration, Web System Login Configuration, File Management, Configuring System Startup, BootLoad Menu Operation. 1. Configuring Telnet Login. Check whether the serial cable is securely Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-6 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-6 Setting the port for connection and communication parameters. A PC may have multiple ports that can be connected to the device. Ensure that the communication parameters you set in the terminal emulation software are consistent with the default parameter settings of the device's console port. Adjust the RTS/CTS configuration as follows: Add to Favorites. Resetting the switch will cause service interruption. To reset the switch, press the button. The endpoint loads the configuration immediately. [~ HUAWEI] user-interface console 0 [~ HUAWEI-ui-console0] speed 4800 [* HUAWEI-ui-console0] flow-control After logging in to a switch for the first time through the console port, perform basic configurations, and set the user privilege level to 15 and authentication mode to AAA for users 0-4 who log in remotely through Telnet. Configure basic information for the Switch, including the date, time, time zone, and name, to facilitate management. Each main control board provides one console port, and the type of the console port is EIA/TIA-232 DCE. interface interface-type interface-number. The default Prepare a serial cable used to connect the serial port on the controller enclosure to the maintenance terminal, and attach a label to the serial cable. Start the terminal emulation software on the PC. Only the S2720-EI, S5720-LI, S5720S-LI, This operation will enable the function of logging in through the console port. All the switches that are delivered most recently and support cloud-based management will have the Huawei device registration query center's URL (register. You can configure parameters based on use and security requirements. Check whether the serial cable is securely I’m trying to connect to my AP-325 via the RJ-45 console port, but only see random characters in terminal, although I set all the necessary settings: Baud rate = 9600 Data bits = 8 Stop bits = 1 Parity = none Flow control = none To log in to a router through a console port for local maintenance, configure a console user interface, including physical attributes, terminal attributes, user levels, and authentication modes. Then the system prompts you the command prompt (for example, < HUAWEI Logging In to the Switch. com) and port number (10020) of the registration query center. When you log in to a router through a console port to configure console user interface attributes, the connection may be interrupted. Insert the DB9 connector of the console cable to the 9-pin serial port on the PC, and insert the RJ45 connector to the console port on the master main control board of the device, as shown in Figure 5-4. This document describes the configurations of Basic, including CLI Overview, EasyDeploy Configuration, USB-based Deployment Configuration, Logging In to a Device for the First Time, CLI Login Configuration, Web System Login Configuration, File Management, Configuring System Startup, ISSU Configuration, BootLoad Menu Operation, Ensure that switches are unconfigured and have no input on the console port. and connect the RJ45 connector to the console port on the device, as shown in Figure 4-5. 1's password: <Huawei> Verifying the Configuration. You may choose different terminal software, such as IPOP and SecureCRT. Click Serial and set the port to be connected and the communication parameters, as shown in Figure 14-2. MGMT port: RJ45: The out-of-band management port is a 10/100/1000M RJ45 autosensing Ethernet port. That is, the sum of the default UTC time zone and offset is equal to the time zone specified by time-zone-name. Connect the RJ45 connector of the console cable to the CONSOLE interface (RJ45) of the router. Instantly find the answers to all your questions about Huawei products and solutions. Flow control mode. The NetEngine 8000 series routers do not support this method to clear the console port password. To be specific, you can hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device. < HUAWEI > clock timezone BJ add 08:00:00 //BJ is the name of the time zone, and 08:00:00 indicates that the Table 2-1 lists the default attribute settings of a console port. Baud rate. This document describes how to configure MQC and ACL-based simplified traffic policies, and provides configuration examples, common matching rules, and actions, as well as the guidance for selecting MQC or ACL-based simplified traffic policies Ensure that switches are unconfigured and have no input on the console port. It must be the same as the mode used Before logging in to a device through a console port, complete the following tasks: Install a terminal emulation program, such as PuTTY, on the PC. The transmission rate on the serial port is low. Figure 4-6 Console Redirection screen. 0. . Typical Operations After Login. Target terminal emulation type for console redirection. Table 4-6 Parameter description. Connect the console port of RouterA to the COM port of Host A using a console cable. For example, in a Windows operating system, you can open Device Manager to view port information and select the port to be connected. Update BootROM system 2. Communication parameters of the terminal emulation software must be consistent with the default attribute settings of the console user interface on the device, which are 9600 bit/s baud rate, 8 data bits, 1 stop bit, no parity check, This button can also be used to restore the default settings with one click. com) and port number (10020) preconfigured. Check whether the serial cable is securely Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-5 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-5 Setting the port for connection and communication parameters. Before setting the current date and time, \Documents Console Cable. Huawei Partner University. Set Port and Connection type to 22 and SSH respectively. Ensure that the communication parameter settings in the terminal Start the terminal emulation software on the PC. If the user authentication mode is set on the user interface of the console port, you can log in to the device only after you are authenticated. Console port: RJ45: Before configuring device login through a console port, you have completed the following tasks: Prepare a console cable. [HUAWEI-console0] authentication-mode aaa //Set the authentication mode to AAA authentication. Terminal Type. Use the terminal simulation software to log in to the device through the console port. 4800bps, 8 data bits,1 stop bits, odd parity check, and no flow Check that the serial port settings on the PC are the same as the console port settings on the switch, as shown in Figure 6-5 The default console port settings are as follows: Baud rate: 9600; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None; Figure 6-5 Setting the port for connection and communication parameters. Run the Create a connection, select the connection port, and set communication parameters. Partner Home. Hard Disk Unit SSD-Sata240G-A; Hard Disk Unit SSD-SATA240G-C; Hard Disk Unit SSD-SATA960G-B; Hard Importing Settings on the USB Device. Back Menu. Therefore, it is recommended that you configure console user interface attributes using other login methods. Parity bit. NOTE: Action. Before setting the current date and time, \Documents Select the port according to your requirements. Configure terminal emulation software, set the connected port and communication parameters, and log in to the Switch. Configuration Examples for CLI Login. minus: subtracts the specified time zone Click Serial to set the connected port and communication parameters, as shown in Figure 9-3. Create a connection, select the port for connection, and set communication parameters. Figure 1 shows the settings in SecureCRT. Before logging in to a device through a console port, complete the following tasks: Prepare a console cable. Flow Control. For details about how to prepare and attach labels, see Engineering Label Specifications for Cables. (02355FDP): Optional. For security purposes, use AAA on the console user interface. Exercise caution when you press the PNP button. [HUAWEI] user-interface console 0 [HUAWEI-ui-console0] authentication-mode password [HUAWEI-ui-console0] set authentication password cipher Huawei@123 Version:V200R020C10. Check whether the serial cable is securely Start the terminal emulation software on the PC. user-interface console 0 [Huawei-ui-console0] authentication-mode password [Huawei-ui-console0] set authentication password cipher Enter Password(<8-128>): [Huawei-ui-console0 it restores the default factory settings The console port and Mini USB port share one internal serial port. You can directly connect a terminal's serial port to the console port to This section uses a Huawei router as an example to describe how to clear a console port password. Start the terminal emulation software on your PC, create a connection, select the connected port, and set communication parameters. OpenSSH has been installed on the client. ; Set the communication parameters. Method 1: Log in to the device using Telnet and change the console port password. Partner Bidding & Network Design Toolkits. Enter the system view. Configure basic information for the Switch, including the date, time, Huawei support community is a communication center for sharing experiences and knowledge, solving questions and problems for enterprise partners, customers and engineers. Which of the following parameter settings for terminal emulation are correct when configuring a Huawei router through the Console port? A. Troubleshooting CLI Login. that the communication parameters you set in the terminal emulation software are consistent with the default parameter settings of the device's console port. system-view-Set the time zone. Default Settings. Check whether the serial cable is securely First Login Through the Console Port. Check whether settings of the terminal communication parameters are consistent with those of the physical attribute parameters on the user interface of the console port. Hardware: Computer, serial port cable, a serial port turn USB cable (computer without Check the settings of serial port terminal software. Use the default settings during configuration. Before logging in to a device locally for the first time through the console port, you have completed the following tasks: that the communication parameters you set in the terminal emulation software are consistent with the default parameter settings of the device's console port. 9600 bit/s. Figure 4-18 shows the deployment process of Huawei intelligent O&M solution, which involves the following two aspects:. Check whether the authentication mode is configured correctly. It provides step-by-step instructions for users to perform fundamental network configuration tasks on a new Huawei switch. Stop bit. Logging In to the Device Through STelnet/Telnet to Set a New Password. Hardware: Computer, serial port cable, a serial port turn USB cable (computer without Click Serial and set the port to be connected and the communication parameters, as shown in Figure 1-13. No flow control. nkvld kfwb roowgi jkxl mueids fekuhe zegx yvu wzegy gnxiy