Fanuc fan bypass parameter. Please contact us if you have any questions.
Fanuc fan bypass parameter Sep 20, 2008 · PARAMETER MANUAL B-63950EN/02 FANUC Series 30*/300*/300*s-MODEL A FANUC Series 31*/310*/310*s-MODEL A5 FANUC Series 31*/310*/310*s-MODEL A FANUC Series 32*/320*/320*s-MODEL A • No part of this manual may be reproduced in any form. (2) Follow the substeps below to enable writing of parameters. A technician told me a simple way to do this by parameter 9900, change 4 to 3 and back. Download. I do not know if you have already one and maybe was broken and someone bypass it by disable parameters for it What do you have on parameter 4002? 06-14-2023, 08:59 AM #5. Check the specific parameters of the drive motor and Created by InShot:https://inshotapp. I'm running a Fanuc 0m system with an Alpha spindle. The procedure is to take out the 2 mm or so that is normal and replace it with 9999, do a zero return, then put the old values back in. Thus really a way to bypass it. If you simultaneously press the RESET and DELETE keys at powerup, you'll clear all SRAM memory (part programs, parameters, offsets, PMC Parameters, Tool Life data, CAP data, etc). The export of this product is We currently have many Fanuc Robodrills with different versions of Fanuc controllers. The little fan will spin fine if you poke it, or a puff a little air over it, but the heart has failed. Alarm Description. That when i use M00 or M01. Buy Points; How it Works; FAQ; Contact Us; Questions and Suggestions; Users; fanuc. We do not have 4th axis's on any machines which cause us to do a lot of fixturing and bringing the machine to the home position then stopping the program with a M0 command, and moving the part to the next position and continuing. Fanuc 16i-LB Parameter Manual. Page 15 FANUC SERVO MOTOR α series This manual mainly assumes that the FANUC SERVO MOTOR αi series of servo motor is used. The parameters for the Fanuc 0 control to reset zero return, are: X=700 Y=701 Z=702 The procedure is: The builder may have provided a method of disabling an axis homing requirement (perhaps by a D-bit that you can set on the Diagnostics page), but it is entirely up to them. fanuc spindle encoder A20B-2001-0590 bypass parameter. 16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i. 7 does the trick but could not find the resource to do so. Convenient method 1) To change parameters in bit unit, press cursor key or , then the cursor becomes bit length and you can set parameters bit by bit (Bit parameter only). At my Fanuc 21i-M control I also have to set some parameters to select the 4th-axis On and Off. • All specifications and designs are subject to change without notice. 100 - PARAMETER WRITE ENABLE. The input device in the foreground is set in parameter No. In section input parameters enter all information to identify controller, axis parameter and address range to be queried. Parameter #19 bit 1 controls the 4th axis neglect function, change it to 1 and the control should ignore the 4th axis not being hooked up. Cary, North Carolina 27513 United States About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Fanuc alarm: 100 - PARAMETER WRITE ENABLE. Page 253FANUC Series 16/18-TB/TC, FANUC Series 0i-TA, FANUC Series 16i/18i/21i-TA/TB About the parameter for output condition of Reference Position Return End Signal 1. If the parameter can be found and the writing operation succeeds FanucParamWrite outputs the new value of the parameter in the right Hello, I run a Tsugami bx12 with a Fanuc LE1 control. Hi everyone, I have a Hardinge T42SP Fanuc 18-T control with sub turret. 1300. However, executing it automatically makes no sense, as the controller reboot is required to apply new soft limits. 04-24-2010, 07:48 PM #12. Typical operation is to measure the casting, then type that measurement At my Fanuc 21i-M control I also have to set some parameters to select the 4th-axis On and Off. To run the machine you must get the parameter list from Fadal. 14 pages. It also includes sections on adjustment procedures, function explanations, and tables of contents for spindle orientation, high-speed Hi frnds,. Parameter 60 bit 2 must be 1 to enagle the ladder display. The Fanuc option has it's own batch of problems too. This document contains a table with 22 rows and 9 columns describing parameters and options for a CNC machine control system. you have to turn off the machine to clear the alarm. net Version: August 2019 V1. If I change it to BYPASS it is changing to ENABLE automaticly. I am using classic S7-315 without Profisafe cards. Enabling parameter write is so simple and basic that I personally am suspect of anyone who want to poke around inside the parameters un-supervised. I checked all the fans I could find, they all worked. haastec. Spent a bunch of time messing with the parameters and trying to work around the scale feedback. It would be on the builder side, like a keep relay. Joined Feb 16, 2007 Location Rhode Island, USA. More details you can email us. So Powering on with parameter write enabling, pressing delete will clear programs and not parameters ? Fanuc 21iT 03-23-2021, 07:44 PM #15. The robot can be recovered by replacing a fan motor May 20, 2017 · Hi frnds,. Turns out there is a fan in the control, mounted all the way up top. It fanuc pluscoders we have stock in our company, and also have ac servo motors, spindle motors etc. 6 for the spindle. this isnt something If a Fanuc Alarm 01 Code is issued during cutting: (a) Investigate the cooling state of the spindle motor. Now repeatability is effecting by 15/20 microns. My CNCzone Login. sinha_nsit. All three axis have linear scale and one failed in Y axis. Spindle orientation parameters: Fanuc: 0i/16i/18i/21i/ 160i / 180i /210i : Usually 4077 In my case the temp sensor on my encoder died on my X axis servo motor. When a fan motor stops on backplane unit, TP shows the following message. For the details of the settings, see the table provided with the description of parameter No. com. Buzzy ramdomly jumpy X axis. 593,319 members. Page 1GE Fanuc Automation Europe Computer Numerical Controls Series 21i -, 210 i - Model B Parameter Manual B-63610 EN/01 TECHNOLOGY AND MORE ; Page 2Ȧ No part of this manual may be reproduced in any form. Press RESET to release alram 100. It contains 3 sections: 1. In one minutes from occurring of alarm, robot stops and cannot be operated from TP. COOLING FAN FAILURE 444 Z AXIS: INV. I was able to clear the alarm once by shutting down/turning back on, however now it won't clear at all and I can't run the machine like this. Loading # 160B 5; 160C 6; 160i; 160 i-LA 4; fanuc Parameter Manual. Fans. Type of applied technical documents FANUC Series 16/18/160/180 - MODEL B PARAMETER MANUAL FANUC Series 16/18/160/180 - MODEL C PARAMETER MAN fanuc alarm | fan motor 0 stop and shutdown | fan motor 1 stop and shutdown#fanucalarm #fanmotor0stopandshutdown #fannotworking #fanmotor1stopandshutdownhell As you know the first and last 2 digits of Txxxx, can have 2 different meanings based on parameters been set. How it Works Log In / Sign Up. . thanks for the help Similar Threads: READ WRITE FANUC PARAMETERS: DESCRIPTION AND USAGE Inventcom · www. • All specifications and designs are subject to change without notice. When I turned it back on it booted with the Set parameter 1023 to -128 for that axis to disable it. I now have it functioning, albeit one problem still needs solving. Important: If you’re using HSSB SETTING PARAMETERS FROM MDI B–63610EN/01 2 SETTING PARAMETERS FROM MDI Follow the procedure below to set parameters. If you have a 0-MC or 0-MD, you can try to display the PMC Ladder by pressing the PARAM/DGNOS key several times. Contribute to CNC Alarms Database. Feb 16, 2022 · B-64700EN/01 PREFACE p-1 PREFACE Applicable models The models covered by this manual, and their abbreviations are : Model name Abbreviation FANUC Series 0i-TF Plus 0i-TF Plus Series 0i-F Plus Series 0i FANUC Series 0i-MF Plus 0 i-MF Plus NOTE 1 For an explanatory purpose, the following descriptions may be used according to we provide fanuc parts maintenance service and also sufficient stock for you, more details please contact us: info@fanuccontroller. Get a second or third opinion on that, because I haven't done it in years. Hello everybody I have a fadal VTC 8030 with a Fanuc 18i that I am having what I believe to be an oscillation problem between my X axis motor and a sca 595,346 members Fanuc 15mb. Not sure there is a parameter that will do what you want. now the problem is controller have ladder have which have 4(a) axis reference condition. I tried to bypass it through 1815#opt but got alarm of SV411 which I avoid by adjust the 1829 parameter. Sent from my G-Tab Quantum using Tapatalk. Programs 9000 to 9999 are used for things like probing, tool-change and all sorts of other important things. ,ltd specialize in FANUC spare parts , we can design test unit for customers, and sufficient stock for fast delivery. 0 Page 7 of 7 FIG 3: Fanuc 31i Model B Parameter output A FIG 4: Fanuc 31i Model B Parameter output B HSSB If your machine has a PC that is connected to the controller via HSSB or you use HSSB features of Unless otherwise noted, the parameter numbers for FANUC Series 16i are used in the text. To display the setting screen, press the function key. How to turn on or off. Do to safety factors, it's probably all controlled in the Ladder, which mayor may not be reconfigurable, especially B-63950EN/02 PREFACE p-1 PREFACE Applicable models The models covered by this manual, and their abbreviations are : Model name Abbreviation FANUC Series 30i-MODEL A 30i –A For machines equipped with FOCAS-enabled Fanuc controllers you can use the utility programs FanucParamReadGui and FanucParamWriteGui to do so. 7 for the door interlock and K0002. I am trying to bypass the door interlock on HAAS machine with Fanuc controller. If my memory serves me correctly, it monitors the fan speed. My requirement is to bypass the fan. Currency: USD USD EUR. May 30, 2014 · Hey Folks, I'm getting fan alarms for both X/Z inverter units, but the fans are working fine. Replaced several of the cabinet cooling fans installed by the machine builder. PARAMETER MANUAL B-64310EN/02 FANUC Series 0+-MODEL D FANUC Series 0+ Mate-MODEL D • No part of this manual may be reproduced in any form. I've checked the drive fans, both the fans inside the yellow cover and the fans on the heat sinks. I am looking for a parameter that will not let them turn parameter write on? Share Add a Comment. Fanuc AC Spindle Motor Alpha i Beta i Move the tool changer arm manually by either turning the fan on the back of the motor or sometimes there is an allen wrench or wrench flat. The new fans above the monitor are also working. Posted via Mobile Device . No part of this Well. Thread starter CatMan; Start date Apr 26, 2012; Replies 7 Views 35,964 C. If you can't get to the position you would like, hold in "P" and "Cancel" on power up to bypass soft overtravels or you could change the soft overtravel limits to The parameters set individual input/output devices if the I/O channels are divided into these four types: input and output in the foreground and input and output in the background. For servo motor and spindle information, refer to the manuals Mar 17, 2017 · When I am in T1 mode it is possible to BYPASS it from MENU->0-> SYSTEM(6)-> DCS(8) ->PROFINET Safety(14) -> Change "ENABLE" to "BYPASS". CNC Machine Control Manufacturer. Since he didn't mention what Fanuc control it is on, the 16/18 chassis are becoming somewhat problematic. B-62560E_02_110525 - Free ebook download as PDF File (. View and Download fanuc 30iB instruction manual online. The export of 4. Its pretty old, from 1994 i think so I know older machines are usually quirky. means there's no way the machine toold builder gave you a way to allow coolant to flow with doors opened other than bypassing the switch or switch signal itself, which would make it I have a Daewoo h63 machine tool with 18 Fanuc control system. The table below indicates the abbreviated model names used with the parameter numbers. means there's no way the machine toold builder gave you a way to allow coolant to flow with doors opened other than bypassing the switch or switch signal itself, which (800) 691-8511 (919) 367-6379; sales@mroelectric. Depending on the machine and if it is a servo motor driven then it sometimes can be rotated by the hand wheel. I did a little googling and it seams that it should be one on the fans that sits up on top of the drives (Fanuc 18i with the Alpha i drives). Is there a way to disable the Y-axis from the Fanuc control parameter write enable PWE . 116 pages. net · info@inventcom. Our shop's new safety consultant decided to turn on all of the door interlocks on our machines. Fanuc 30i 31i 32i Operator Manual B-63944EN04. The ballscrew did not seem really bad . All these resulted Coatings 2022, 12, 1979 6 of 38 in reduced efficiency of the engine and an increased consumption of fuel. Fanuc 20-FA Parameter Manual B-62180E/01. txt) or read book online for free. In normal mode, there is no movement with g01 when the spindle motor stops. Re: Disable overtravel alarm (regardless of control) Originally Posted by Jacek3743. PWE=1 Memory Switch: the machine doesn't have one, allowed me to write normal It's been a while, but our 21iT did something very similar recently. After the parameters have been input, set PARAMETER WRITE on the SETTING screen to 0. Each row lists a parameter number, bit configuration, and text description in English of the corresponding option. Please use caution. FANUC FAN 3106KL-05W-B59, this item original disassemble, perfect testing, one year warranty, non-human quality problems within 15 days package returned, while supporting the maintenance business, providing free technical advice. B button, when you prees output / punch. Please contact us if you have any questions. Telegram; Facebook; Instagram; LinkedIn; YouTube; Categories. sales-2@tzswcnc. Thats why I suggested the 9900 parameter, at his control maybe an other number. I don't think anybody here is going to answer you unless there is a full assessment of the situation If you don't know what those signals are, you're best reading the "Dual Check Safety Function" manual and attending FANUC's DCS training. Alarm 444 X AXIS: INV. The shop turned off the air yesterday at lunch and all the machines alarmed out with the "low air pressure" alarm. Categories Common. I was confused about the input unit though. (1) Place the NC in the MDI mode or the emergency stop state. We fixed it by replacing the encoder. To turn the scales off you must change the following parameters: 1815 bit 1 to a 0. P. Page 1FANUC Series 16*-MODEL B FANUC Series 18*-MODEL B FANUC Series 160*-MODEL B FANUC Series 180*-MODEL B FANUC Series 160*s-MODEL B FANUC Series 180*s-MODEL B PARAMETER MANUAL B-63530EN/03 ; Page 2• No part of this manual may be reproduced in any form. There are several different ones Fanuc 30i 31i 32i Parameter Manual. Now geometry offset + wear offset are related to the last 2 Learn how to solve the Fanuc 701 overheat fan motor alarm with this video guide. Thank you for watching. It describes: - How to display parameters using the CNC control. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Wasn't pointed out in the Fanuc parameter manual for my machine. Fanuc 3T Parameters Manual. 2) To set data consecutively, use EOB key. On our Fanuc 0i-M machines it is a K-bit that has to be toggled under the PMC parameters. "bypass an E-stop" is not something you should be doing. When using any other model, reference the corresponding parameter numbers. 5 for our fanuc Oi-mate. Can you please suggest that what I missed ? or what next I need to do? Axis Limit Parameter on Fanuc 18i. In other words, you most likely don't have the option to edit them without a special code TYPED IN by a fanuc employee. There is most likely a Unlock Programs Fanuc Parameter, first of all you’ll need to go to the setting screen and change the parameter write box to a 1. Move the mill to the farthest location you want to travel and then look at the axis "Machine" location in the all Songwei cnc machinery co. Otherwise, replace the cooling fan. Views: 234125 . 1 it’s not labeled but it’s between LMS and OUT parameter. page. View Profile Originally Posted by Don18P. This document is the Parameter Manual for FANUC Series 15/150-Model B CNC systems. link/YTShare In my integrex, a simple parameter change by a service tech led to an extemely loud bang and destroyed a tool and toolholder, knocking 2 spindles out of alignment in the process. Sort by: You can bypass overtravel switches and cause some very serious crashes, turn scales on/off depending on the machine, change Pl let me know the procedure to download the parameter in GE Fanuc 15M system, we procure one used m/c there was no any battery in the system therefor all data lost, pl help us. Thank you hi all, we have Lokesh vmc 800 machine with Fanuc oi-md control MTB have made this with 4 axis but we need need only 3 axis. 4 days ago · fanuc spindle encoder bypass parameter Encoder. Due to accidental parameter memory reset, I've been struggling to get the machine working again by manually entering the parameters. Advertisement. - How to output parameters to and input parameters from an external device through the RS-232C interface. Every parts will 100% test ok before delivery. As this parameter is axis independent axis was set to 0. This isn't an area to be experimenting on your What are the 3 Parameter numbers for the 0M that set the overtravel limit. Now it's very quick and easy to disable the 4th-axis. Log in. How to bypass fan alarm. If the cooling fan is stopped, check the power supply. Page 1FANUC Series 30*/300*/300*s-MODEL A FANUC Series 31*/310*/310*s-MODEL A5 FANUC Series 31*/310*/310*s-MODEL A FANUC Series 32*/320*/320*s-MODEL A PARAMETER MANUAL B-63950EN/02 ; Page 2• No part of this manual may be reproduced in any form. 02-17-2014, 03:26 PM #3. Again it is a Fanuc Oi-MD control on a Chevalier QP2026 milling machine Thanks Drew . The motor contactor on the sub turret servo amp went bad. GE Fanuc Automation Computer Numerical Control Products Parameter Manual GFZ-62560E / 02 March 1997 Warning Warning notices are used in this publication to emphasize that hazardous voltages, currents, temperatures, or other conditions exist in this equipment or B-65280EN_01 - Free ebook download as PDF File (. 2175 pages. The address is K0002. There is no separate file for the axis limits only, but you can write a small TP program for this. If you need claification on how to get to these addresses let me know. Sent from my G-Tab Quantum using Tapatalk 02-17-2014, 08:26 PM #3. It contains definitions of warnings, cautions, and notes. If you access your controller via network enter the IP Address or DNS Hostname. - How to set parameters from MDI mode by inputting commands. 7. systems- parameter- pmc-keeper- 2. Fanuc 0i/0i Mate Fanuc 10/11/12 Fanuc Series 15 Fanuc 15i Fanuc 16i 18i Fanuc 21 Fanuc 21i Fanuc Alarms Fanuc Spindle Alarms Fanuc 6M 6T Alarms RADIATOR FAN FAILURE Fanuc Alarm Description PSM: The external radiator stirring fan failed. xxxxxx0x (x = don’t change) 1820 = 2 2084 = 1 2085 =100 2024 = 12500 These will only allow you to move for testing only. zavateandu. One way to check this (on my 18i-TB control) is to go to to (hard key) System (soft key) Dgnos then page down to number 308 which should show the servo temp or 309 shows the pulse coder temp. Help grow and collaborate one of hello friend in this video I am going to tell you how to solve the alarm DS 0609 region and its complete solution so please watch the video until the last an This document provides instructions for displaying, setting, and inputting/outputting CNC parameters through various interfaces. All are spinning and moving air. 5. This document provides a parameter manual for FANUC AC SPINDLE MOTOR @* series. The cycle time keeps running and I am wondering if there is a parameter that will change it to make it stop at the M00 or M1. Electrify. it differs for every machine builder. Ȧ All FANUC 0i MODEL D the axes use a pulse coder + linear scale to know it's position I want to remove the linear scale from the Y axis. com fanuc fan bypass parameter for cnc machinery driver Songwei cnc machinery co. COOLING FAN FAILURE 608 X AXIS: INV. i need to bypass it 4(A) axis, from controller i changed parameter 8130-3 there is no 6. So beware back em up ASAP. (i don't care of the accuracy) I tried to remove it but these alarms appeared: DS0300 (Y)APC ALARM: NEED REF RETURN DS0307 (Y)APC ALARM: BATTERY LOW 1 If you turn off parameter 1815 Make all 0's 00000000 you Pressing RESET at power up only clears out the Parameters and Offsets. What is Encoder An encoder is an electromechanical device that is used to measure motion or position in form of digital signal and also used in many industries to provide Read more. This should reset the NE9 parameter because the part programs will be wiped. Input format was set to DWord (long). Please like and subscribe to our channel for encouraging us for creating more video which will be more informative and helpful to incr Theres tricks to both parameters and programs. How to (1) Place the NC in the MDI mode or the emergency stop state. The spindle drive motor runs at S-command speed just as intended, but as I have 2:1 ratio Pulled monitor panel and replaced both fans above the circuit board cage. turning on/off #9000's can be like a bomb and cost you some real money to un do. Programs you have to disable NE8 & NE9 parameters, so it allows them to be edited, which includes outputting them. fanuc-All-Options-16i-18i-o-15-21-Parameter-9900 - Free download as PDF File (. 02-15-2024, 02:43 PM #17. B-63950EN/02 PREFACE p-1 PREFACE Applicable models The models covered by this manual, and their abbreviations are : Model name Abbreviation FANUC Series 30i-MODEL A 30i –A Series 30i FANUC Series 300i-MODEL A 300i–A Series 300i FANUC Series 300is-MODEL A 300is–A Series 300is FANUC Series 31i-MODEL A 31i –A FANUC Series 31i-MODEL A5 31i –A5 Hi! All, I have one drill tap center with Fanuc Oi-MF. Mar 2, 2017 #2 You can change the soft limits with parameter 1320 and 1321. FANUC Series 30+-MODEL B FANUC Series 31+-MODEL B FANUC Series 32+-MODEL B. Continue with reading or go to download page. Regards, Heavy_Metal. We have 28 Fanuc Parameter manuals for free PDF download. The Bridgeport XR1000 sat for a short spell and now I'm getting a 606 alarm Axis cooling fan fault. I heard K11. I ordered a couple with my fingers crossed that that is the problem. Move the axis to where you think zero return should be. In this manual we have tried as much as possible to describe all the various matters. 1st off- We use an EmcoTurn 320 with Fanuc O-T control. Apr 26, 2012 #1 Background: I have a dedicated mill that does machining on some semi-rough castings. I have had a couple of situations that an operator has changed some parameters on Fanuc 18-i series controls. 1. so unplugged all connectors and unplugged rotary axis. But I don't know which parameters should I change in Fanuc 32i. A20B-2001-0590. My controller R30iA is equipped with cooling fan on empty rack nearby cpu module. I'm not responsible for you changing anything in your machine. View Profile View Forum Posts Registered Join Date Feb 2006 Posts 1792. Control Model. Under Port enter the port number configured for the FANUC Focas option at the controller, default 8193. I now have parameter backup and i have succesfully passed the normal parameters via the rs232 port. Our elderly Fanuc OM controlling the Kondia crashed while downloading a program. But in T2/Auto mode it is not possible. com; MRO Electric and Supply 1652 Old Apex Rd. Aug 27, 2017 · I do not think so. Since aerospace technology needs accuracy and high safety standards fanuc ac servo motor α series descriptions b-65142e fanuc ac servo motor α series parameter manual b-65150e fanuc ac spindle motor α series descriptions b-65152e fanuc ac spindle motor α series parameter manual b-65160e fanuc servo amplifier α series descriptions b-65162e fanuc servo motor α series maintenance manual b-65165e Then the temp fan gets mounted in for the long haul. 08-25-2016, 11:26 AM #4. f15 Parameter Manual - Free ebook download as PDF File (. Reply with Quote. Parameters, I'm going to say, you have to press and hold the E. Product name Abbreviated model name in text Page 1FANUC AC SPINDLE MOTOR @* series FANUC AC SPINDLE MOTOR #* series PARAMETER MANUAL B-65280EN/05 ; Page 2• No part of this manual may be reproduced in any form. Hello again, i had a parameter loss on my machine. So I turned it off and back on. inventcom. You can not run the machine with these values. I am thinking about a configuration where the first 2 digits determine Turret station number + Geometry offset. +86 18616796852. Fanuc. You have to pull the sdu out. (2) Follow the My controller R30iA is equipped with cooling fan on empty rack nearby cpu module. I am trying to open the door and lock the fixture and rotate the angle to lock the fixture and then continue with the program afterward. Just pu Fanuc Cooling Fan Bypass Parameter Timothy Polashek HVAC Control in the New Millennium Michael F. Read Download. alexfanuc. The products in this manual are controlled based on Japan’s “Foreign Exchange and Its not a Fanuc parameter. View Profile View In this example parameter 6713 (Parts required) was set to +155 via network on a controller with DNS Hostname FANUC. CatMan Hot Rolled. Recommended. Regardless if you own the rights to the parameters OR NOT, be careful what you change assuming you can change them. Its not a Fanuc parameter. 20. Same symptoms, run for a few minutes, then alarm saying it was overheating, and a fan motor wasn't running. txt) or read online for free. pdf), Text File (. Songwei cnc machinery co. Joined Apr 12, 2005 Location Brandon, MS. Post your own comments and CNC tips. Recently came my A02B-0047-C902 fan unit. Pipes Hot Rolled. I have a problem on Fanuc CNC control. O. 6. However the machine really needs the diagnostic parameters to work. View Profile View Forum Posts Registered Join Date Oct 2009 Posts I did this last week on my machine with the 0m-C control, it's a different brand but it may work the same. Is there such a command to do so. When i disconnect fan it shows alarm. #9000's are controlled. Hordeski,2001 1-Heat, Ventilation and Damper Control Trends2-Energy and Power Management, Distributed Control Trends3-Control Technology, Microelectronics and Nanotechnology4- Zero Return parameter setting procedure for Fanuc 16/18 and 16i/18i Controls . eknxdvdbpyyevsixiiucltcblwruwbweoautpeeaywljyaywfjk